Self-Centering Damage-Free Seismic-Resistant Steel Frame Systems (Concentrically-Braced Frame)


Print Friendly

Objectives

The overall project objective is to investigate a family of innovative self-centering (SC) steel frame systems which will withstand without damage the currently accepted design basis earthquake (DBE) for buildings. This current project task is focusing on the design and experimental performance of a self-centering concentrically braced frame (SC-CBF). The SC-CBF test structure was designed using performance-based design criteria for immediate occupancy under a median-level DBE and collapse prevention under the Maximum Considered Earthquake (MCE). This expected performance will be assessed and the design criteria verified through hybrid-pseudo-dynamic experiments on a 0.6-scale 1-bay 4-story SC-CBF.

Earthquake Simulations

1. Introduction

The SC-CBF configuration being tested is a one-bay four story concentrically braced frame with post-tensioning bars positioned in the middle of the frame and running vertically from a roof anchorage system down to a “basement” anchorage system.  This setup is shown in Figure 1 and Figure 2.  Other items of note in the test structure are that the floor system is supported by gravity columns that are adjacent to the rocking SC-CBF and that inertial forces are transferred from the floor system through the gravity columns to the SC-CBF through lateral load bearings.  The lateral load bearings are shown in Figure 3.  The SC-CBF structure being tested is designed using a performance-based design (PBD) approach for immediate occupancy (IO) under a median DBE and collapse prevention (CP) under a median MCE.  These performance objectives are outlined graphically in Figure 4.

2. Experimental Program

The SC-CBF test frame was designed using the performance-based design (PBD) approach assuming that the SC-CBF is the lateral force resisting system for a 6×6-bay 4-story prototype building located on stiff soil (Site Class D (ASCE 7-05)) in Van Nuys, California. The 0.6 scale floor plan for this prototype building is shown in Figure 5.  A total of eight SC-CBF frames would be in the building.  One of these SC-CBF frames was tested in the laboratory while the gravity system of one-quarter of the building was modeled on the computer using a technique known as hybrid simulation.  Preliminary stiffness tests of the frame were performed.  Five DBE and five MCE scaled ground motion records, as well as one extreme MCE (xMCE) record, were used in the hybrid simulation.  The hybrid simulation uses Rayleigh damping with 2% damping in the 1st mode and 5% in the 3rd mode. The explicit unconditionally stable CR integration algorithm is used to solve the equations of motion.  Additional tests were performed at the frequently occurring earthquake (FOE) level and DBE level in fast hybrid simulations (near real-time load rates).  The test matrices for the pseudo-dynamic tests and fast hybrid tests are shown in Table 1 and Table 2 respectively.

3. Related Publications

Roke, D.; Sause, R.; Ricles, J.M.; Seo, C.-Y.; and Lee, K.-S. (2006). “Self-Centering Seismic-Resistant Steel Concentrically-Braced Frames,” Proceedings of the 8th U.S. National Conference on Earthquake Engineering, EERI, San Francisco, April 18-22.

Sause, R., Ricles, J.M., Roke, D., Seo, C.-Y., and Lee, K.-S. (2006), “Design of Self-Centering Steel Concentrically Braced Frames,” 4th International Conference on Earthquake Engineering, Taipei, Taiwan.

4. Participants

Graduate Research Assistant

  • David Roke
  • Nathanial Gonner
  • Brent Chancellor

Faculty Advisors

  • Richard Sause
  • James Ricles

Post-Doctoral Research Associates

  • Choung-Yeol Seo

Table 1 – Hybrid Simulations

Test Name Input Level Event Station Component Scale Factor
DBE_5108-090_12-31-2009 DBE 1994 Northridge Santasusana 090 2.49
DBE_cls000_12-31-2009 DBE 1989 Loma Prieta Corralitos 000 0.73
DBE_h-shp270_B_12-31-2009 DBE 1979 Imperial Valley Sahop Casa Flores 270 1.75
DBE_arl090_01-04-2010 DBE 1994 Northridge Arleta 090 1.40
DBE_arl090_01-06-2010 DBE 1994 Northridge Arleta 090 1.40
MCE_stn110_01-07-2010 MCE 1994 Northridge LA – Saturn 110 1.98
MCE_a-tmz270_01-07-2010 MCE 1976 Friuli, Italy Tolmezzo 270 2.55
MCE_lp-hda255_01-08-2010 MCE 1989 Loma Prieta Hollister Diff Array 255 2.24
DBE_nr-pel360_01-08-2010 DBE 1994 Northridge Hollywood Storage FF 360 1.55
MCE_cap000_01-11-2010 MCE 1989 Loma Prieta Capitola 000 1.45
MCE_h-cpe237_01-13-2010 MCE 1979 Imperial Valley Cerro Prieto 237 3.85
xMCE_tak090_01-13-2010 MCE 1995 Kobe, Japan Takatori 090 0.90
MCE_lp-hda255_01-28-2010 MCE 1989 Loma Prieta Hollister Diff Array 255 2.24
MCE_lp-hda255_02-02-2010 MCE 1989 Loma Prieta Hollister Diff Array 255 2.24
xMCE_tak090_02-05-2010 MCE 1995 Kobe, Japan Takatori 090 0.90
DBE_5108-090_A_02-09-2010_60pctPT DBE 1994 Northridge Santasusana 090 2.49
DBE_5108-090_B_02-09-2010_0pctPT DBE 1994 Northridge Santasusana 090 2.49

Table 2 – Fast Hybrid Simulations

Test Name Input Level Event Station Component Scale Factor
FOE_b-krn270_B_02-03-2010_10x-2_RT FOE 1987 Superstition Hills KRN 270 1.08
FOE_b-krn270_E_02-03-2010_4x-3_RT FOE 1987 Superstition Hills KRN 270 1.08
DBE_cls000_A_02-03-2010_10x-1 (Ktfx2)_RT DBE 1989 Loma Prieta Corralitos 000 0.73
DBE_cls000_B_02-03-2010_10x-2 (Ktfx3)_RT DBE 1989 Loma Prieta Corralitos 000 0.73


Figure 1 – Test Frame Setup

(a)

(b)

Figure 2: (a) Test frame in the laboratory; (b) schematic of test setup

Figure 3: Friction bearing (a) drawing; (b) photograph of bearing from beneath

Figure 4 – Schematic of performance-based design criteria

Figure 5 – Prototype Building: (a) floor plan; (b) elevation of SC-CBF

SCCBF Being Removed From ATLSS After Testing

Figure 6 – SCCBF Being Removed

Link to Timelapsed Videos

  • Categories

    • News and Events (44)
    • Project Spotlight (8)
  • Recent News

    • Real-time Hybrid Simulations of a Large-scale Steel Structure with Nonlinear Viscous Dampers
    • RTHS being performed this week
    • Simulating Earthquakes by Combining Analytical Models with Physical Structures
  • Archives

    • ► 2013
      • Real-time Hybrid Simulations of a Large-scale Stee … (04/30)
      • RTHS being performed this week (02/21)
    • ► 2012
      • Simulating Earthquakes by Combining Analytical Mod … (12/19)
      • Hybrid Simulation Data Model now supported with NE … (06/14)
      • Researchers probe how strong buildings must be to … (03/20)
    • ► 2011
      • Advances in Real Time Hybrid Simulation Workshop (08/26)
      • Upcoming workshop (08/16)
      • Seismic Hazard Mitigation using Passive Damper Sys … (03/21)
      • Distributed RT Hybrid Testing (03/17)
      • Pictures from William Allen HS Field Trip (03/08)
      • Student Field Trip this Friday (02/22)
      • Testing on passive damping systems (02/18)
      • NEES equipment maintenance (01/17)
      • "Megaquake 10.0" History Channel Special … (01/11)
    • ► 2010
      • MR Damper Projects (12/28)
      • SteelDay 2010 (09/24)
      • ATLSS Welcomes the 2010 NEES REU Students (06/01)
    • ► 2009
      • Three ATLSS Center researchers honored by American … (07/08)
      • ATLSS welcomes the 2009 REU Students (05/27)
      • Lehigh Webinar for RTMD users (02/18)
    • ► 2008
      • NEESR-SG: Self-Centering Damage-Free Seismic-Resis … (11/06)
      • NEESR-SG: Self-Centering Damage-Free Seismic-Resis … (10/31)
      • NEESR-SG: Self-Centering Damage-Free Seismic-Resis … (10/28)
      • NEESR-SG: Self-Centering Damage-Free Seismic-Resis … (10/21)
      • NEESR-SG: Self-Centering Damage-Free Seismic-Resis … (10/17)
      • ATLSS involved in Discovery Channel program (09/25)
      • "The Works" highlights ATLSS (08/25)
      • RTMD hosts Launch-IT (07/23)
      • ATLSS Seminar: Overview of Structures for 2008 Oly … (05/28)
      • 2008 NEES REU program begins (05/27)
      • Germantown High students get all shook up on field … (05/14)
      • 3D Model Panel for RDV Update (03/19)
    • ► 2007
      • RTMD Highlights for November, 2007 (11/01)
      • RTMD Highlights for October, 2007 (10/01)
      • RTMD Highlights for September, 2007 (09/01)
      • RTMD Highlights for June, 2007 (06/01)
      • RTMD Highlights for May, 2007 (05/01)
      • RTMD Highlights for February, 2007 (02/01)
    • ► 2006
      • RTMD Highlights for November, 2006 (11/01)
      • RTMD Highlights for July, 2006 (07/01)
      • RTMD Highlights for June, 2006 (06/01)
      • RTMD Highlights for May, 2006 (05/01)
      • RTMD Highlights for April, 2006 (04/01)
      • RTMD Highlights for March, 2006 (03/01)
      • RTMD Highlights for February, 2006 (02/01)
      • RTMD Highlights for January, 2006 (01/01)
    • ► 2005
      • RTMD Highlights for December, 2005 (12/01)
      • RTMD Highlights for November, 2005 (11/01)
      • Hybrid Testing Workshop in San Diego (10/01)
      • E-Defense Workshop (08/01)
      • Self Centering Workshop (06/01)
    • ► 2004
      • NEES@Lehigh begins (10/01)
  • May  2013
    SMTWTFS
     1234
    567891011
    12131415161718
    19202122232425
    262728293031 
  • Equipment Calendar

    [site map] Copyright © 2013 · All Rights Reserved · Lehigh University
    This site is supported by the George E. Brown, Jr. Network for Earthquake Engineering Simulation (NEES) Program of the National Science Foundation under Award Number CMMI-0927178